7,5kVA – Single Phase

Model: AAP 8000 DE3

Voltage: 380
Standby Rating (EPS): 6,5kW / 8,2kVA
Prime Rating (PRP): 6,00kW / 7,5kVA
Standby Amper: 11,3
Dimensions: (L) 730 x (W) 490 x (H) 690mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

12kVA – 3 Phase

Model: APD 12 A

Voltage: 400/231
Standby Rating (EPS): 9,20kW / 11,50kVA
Prime Rating (PRP): 8,48kW / 10,60kVA
Standby Amper: 16,60
Dimensions: (L) 1400 x (W) 760 x (H) 927mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

16kVA – 3 Phase

Model: APD 16 A

Voltage: 400/231
Standby Rating (EPS): 12,40kW / 15,50kVA
Prime Rating (PRP): 11,60kW / 14,50kVA
Standby Amper: 22,37
Dimensions: (L) 1400 x (W) 760 x (H) 927mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

25kVA – 3 Phase

Model: ADP 25 A

Voltage: 400/231
Standby Rating (EPS): 20kW / 25kVA
Prime Rating (PRP): 18,40kW / 23,0kVA
Standby Amper: 36,09
Dimensions: (L) 1933 x (W) 963 x (H) 1213mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

33kVA – 3 Phase

Model: ADP 33 A

Voltage: 400/231
Standby Rating (EPS): 26,40kW / 33kVA
Prime Rating (PRP): 24,00W / 30,00kVA
Standby Amper: 47,63
Dimensions: (L) 1500 x (W) 900 x (H) 1061mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

40kVA – 3 Phase

Model: ADP 40 A

Voltage: 400/231
Standby Rating (EPS): 32kW / 40kVA
Prime Rating (PRP): 28,80W / 36,00kVA
Standby Amper: 57,74
Dimensions: (L) 1730 x (W) 900 x (H) 1138mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

50kVA – 3 Phase

Model: ADP 50 A

Voltage: 400/231
Standby Rating (EPS): 40kW / 50kVA
Prime Rating (PRP): 36,00W / 45,00kVA
Standby Amper: 72,17
Dimensions: (L) 1860 x (W) 900 x (H) 1340mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

70kVA – 3 Phase

Model: ADP 70 A

Voltage: 400/231
Standby Rating (EPS): 56kW / 70kVA
Prime Rating (PRP): 51,20W / 64,00kVA
Standby Amper: 101,04
Dimensions: (L) 963 x (W) 1452 x (H) 1380mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

90kVA – 3 Phase

Model: ADP 90 A

Voltage: 400/231
Standby Rating (EPS): 74,40kW / 93kVA
Prime Rating (PRP): 68,00W / 85,00kVA
Standby Amper: 134,24
Dimensions: (L) 963 x (W) 1452 x (H) 1380mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

110kVA – 3 Phase

Model: ADP 110 A

Voltage: 400/231
Standby Rating (EPS): 88,00kW / 110kVA
Prime Rating (PRP): 80,00W / 100,00kVA
Standby Amper: 158,78
Dimensions: (L) 1250 x (W) 1000 x (H) 1469mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

145kVA – 3 Phase

Model: ADP 145 A

Voltage: 400/231
Standby Rating (EPS): 116,00kW / 145kVA
Prime Rating (PRP): 105,60W / 132,00kVA
Standby Amper: 209,30
Dimensions: (L) 2290 x (W) 1000 x (H) 1474mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

200kVA – 3 Phase

Model: ADP 200 A

Voltage: 400/231
Standby Rating (EPS): 160,00kW / 200kVA
Prime Rating (PRP): 144,00W / 180,00kVA
Standby Amper: 288,68
Dimensions: (L) 2336 x (W) 1100 x (H) 1652mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

275kVA – 3 Phase

Model: AD 275

Voltage: 400/231
Standby Rating (EPS): 220,00kW / 275kVA
Prime Rating (PRP): 200,00W / 250,00kVA
Standby Amper: 396,94
Dimensions: (L) 3960 x (W) 1356 x (H) 2167mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

330kVA – 3 Phase

Model: AD 330

Voltage: 400/231
Standby Rating (EPS): 330,00kW / 264kVA
Prime Rating (PRP): 300,00W / 240,00kVA
Standby Amper: 433,00
Dimensions: (L) 2950 x (W) 1300 x (H) 1588mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

410kVA – 3 Phase

Model: AD 410

Voltage: 400/231
Standby Rating (EPS): 328,00kW / 410kVA
Prime Rating (PRP): 300,00W / 3750,00kVA
Standby Amper: 591,80
Dimensions: (L) 4460 x (W) 1610 x (H) 2480mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

510kVA – 3 Phase

Model: AD 510

Voltage: 400/231
Standby Rating (EPS): 510,00kW / 408kVA
Prime Rating (PRP): 460,00W / 368,00kVA
Standby Amper: 664,00
Dimensions: (L) 3150 x (W) 3106 x (H) 1550mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

580kVA – 3 Phase

Model: AD 580

Voltage: 400/231
Standby Rating (EPS): 580,00kW / 464kVA
Prime Rating (PRP): 525,00W / 420,00kVA
Standby Amper: 758,00
Dimensions: (L) 3106 x (W) 1550 x (H) 1944mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

630kVA – 3 Phase

Model: AD 630

Voltage: 400/231
Standby Rating (EPS): 630,00kW / 504kVA
Prime Rating (PRP): 575,00W / 460,00kVA
Standby Amper: 830,00
Dimensions: (L) 3960 x (W) 1356 x (H) 2167mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.

750kVA – 3 Phase

Model: AD 750

Voltage: 400/231
Standby Rating (EPS): 750,00kW / 600kVA
Prime Rating (PRP): 680,00W / 544,00kVA
Standby Amper: 982,00
Dimensions: (L) 4190 x (W) 3494 x (H) 1550mm

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.
PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.